Strain/Weighing Instrumentation - Back to Product Guide
Made in Santa Ana, CA
Electromagnetic Compatibility
Underwriter Laboratories
Underwriter Laboratories
Year 2000 Compliant
HANDBOOK 44 SCALE METER
INFINITY Handbook 44 Scale Meter
NTEP CERTIFICATION #92-152
The INFW scale meter is a microprocessor-based indicator/ controller with enhanced features that allow you to easily configure the unit for virtually any application. It is compatible with most strain gage sensors such as load cells and pressure transducers.

Shown with LC101 Series
Load Cell Sold Seperately

Mechanical Reference
Price List
INFW
Selectable Scale Divisions, Selectable Classes I (III, IIIL, or IV) and Handbook 44 Certification
6 Digits
2 or 5 Coordinate Linearization of Input Signals
Four Isolated Open Collector Outputs
Wide Selection of dc Voltage and Current Ranges
Ratiometric Inputs
Tare-Fixed, Auto or Sequential
1.5 to 11 and 24 Vdc Sensor Excitation
Large Digital Offset Capabilities Enabling Easy Scaling in Engineering Units
Smart Filtering Detects the Difference Between a Spike or Process Change (Patent Applied For)
Selectable Decimal Point and Read Rates of up to 13 Readings/Sec
Peak and Valley Detection and Memory
Configurable Via Front Pushbuttons or Via RS-232 or RS-485


OPTIONS
Isolated Dual 7 Amp Form C (SPDT) Relays
Isolated Parallel BCD Output
Isolated Analog Output of 0-10 Vdc, 0-5 Vdc, 1-5 Vdc, 0-20 mA dc and 4-20 mA dc
Isolated Serial RS-232
Isolated RS-485, Addressable up to 199 Units


The INFINITY® scale meter can be configured, via the five front-panel pushbuttons and/or the optional serial communications boards, to accept any of a variety of dc voltage ranges (some ranges plus unipolar or bipolar are first selected via a jumper located at the top of the instrument housing) and display them in engineering units.

Standard features include normal or sequential tare, peak or valley recall, tare limit, and a high resolution A/D converter with digital scaling and offset. Other features include dual relay or BCD output, isolated analog output, RS-232 or RS-484 serial communications options, auto or sequential tare, class selection, and display of units of measure. Self-diagnostics are performed automatically on power-up.

These meters provide both software and hardware lockout configurations which let you define the parameters, from setpoint adjustment to total reprogramming. Users can scale and offset their input signal into any engineering units desired. This is accomplished by the use of an exclusive two or five data point method of scale and offset for linearization of input signals transmitted from a sensor. The meter provides a choice of sensor excitations of 1.5 to 11 Vdc or 24 Vdc for sensors such as load cells, strain gages, and pressure transducers.



INFZW Split Meter INFZW Split Meter
Mechanical Reference
Price List
Self-Adjusting
Weight Assemblies

TWA5 Load Cell Included
Specifications
TWA5 Load Cell
Available from
OMEGADYNE, INC.

SPECIFICATIONS

Accuracy: ▒0.005% rdg
Span Temperature Coefficient: ▒15 ppm/░C
Step Response: 1 sec to 99.9%
Warmup to Rated Accuracy: 55 min
Operating Ambient: 0 to 50░C (32 to 122░F), 95%RH, non-condensing
Storage Ambient: -40 to 85░C (-40 to 185░F)
Power: 115 or 230 Vac, 49-400 Hz; 10 to 32 Vdc
Power Consumption:
6 W nominal, 10 W max.
Normal Mode Rejection: 60 dB
Common Mode Rejection: 120 dB
Common Mode Voltage: 1500 V peak per Hv test
Conversion: dual-slope technique
Reading Rate: 3/sec or 13/sec, 60 Hz; 3/sec or 12/sec, 50 Hz
Display: red or green 6-digit, 14-segment, 13.7 mm (0.54"); 4 alarm indicators
Dimensions: 48 H x 96 W x 165 D mm (1.89" x 3.78" x 6.5")
Panel Cutout: 45 H x 92 W mm (1.772" x 3.622"); 1/8 DIN
Weight: 574 g (1.27 lb)
TTL Outputs: four, isolated open collector; rated 150 mA at 1 V sink, 30 V open
BCD Output: isolated, tri-state, TTL/CMOS compatible; external 5 V supply for isolated; internal 5 V supply for non-isolated
Dual Relays: form C, 7 A at 30 Vdc or 230 Vac
Four Relay Option: dual 7A relays and dual 1 A relays
Analog Output: 0-5 V/1-5 V/0-10 V/0-20 mA/4-20 mA, user selectable; 354 Vp isolation; 15-bit resolution; 0.1% accuracy, 50 msec step response
RS-232 Communications: 300/600/1200/2400/4800/9600/19.2k baud; RJ11 4-wire connection; complete program setup and message display capability; programmable to transmit current display, alarm status, min/max, actual measured input value and status
RS-485 Communications: 300/600/1200/2400/4800/9600/19.2k baud; RJ12 6-wire connection; addressable from 0 to 199
Voltage Input Ranges: 0-100 mV, 0-1 V, 0-5 V, 1-5 V, 0-10 V, 0-100 V, ▒50 mV, ▒500 mV, ▒5 V, ▒50 V
Current Input Ranges: 0-20 mA, 4-20 mA
Input Configuration: single-ended
Polarity: unipolar/bipolar, programmable
Span Adjustment: +0.00001 to 500,000, programmable
Offset Adjustment: 0 to 999,999 or 0 to -99,999; programmable
Sensor Excitation: 10 V at 30 mA for bridge; 24 V at 25 mA for loop power


To Order (*insert number code to complete model #) Prices Shown in U.S. Dollars
Basic Model
Power/ Display
Control Output
Analog Output
Serial Output
Input Signal
Description
Price
INFW
( * )
( * )
( * )
( * )
( * )
Strain gage/load cell panel meter
$545
INFZW
( * )
( * )
( * )
( * )
( * )
Strain meter with remote display
$595
 
0
        115 Vac power, red LED display
N/C
 
1
        230 Vac power, red LED display
N/C
 
2
        115 Vac power, green LED display
N/C
 
3
        230 Vac power, green LED display
N/C
   
0
      Four NPN open collector transistors
N/C
   
1
      Isolated parallel BCD
$110
   
2
      Two 7 A relays
$75
   
3
      Two 7 A relays and two 1 A relays
$175
     
0
    No analog output
N/C
     
1
    Isolated analog output
$110
       
0
  No serial output
N/C
       
1
  Isolated RS-232
$110
       
2
  Isolated RS-485
$110
         
( * )
Specify range signal from chart below.*
N/C

INPUT SIGNAL
Range Code
Range
Range Code
Range
Range Code
Range
DC1
0-100 mV
DC5
0-10 Vdc
DC9
▒5 Vdc
DC2
0-1 Vdc
DC6
0-100 Vdc
DC10
▒50 Vdc
DC3
0-5 Vdc
DC7
▒50 mVdc
C1
0-20 mA
DC4
1-5 Vdc
DC8
▒500 mVdc
C2
4-20 mA

OPTIONS
Model
Description
Price
Model
Description
Price
BL
Blank Lens
$15
9SC4
9-pin RS-485 connector
$30
FS
Special Calibration
$25
25SC2
25-pin RS-232 connector
$30
9SC2
9-pin RS-232 connector
$30
25SC4
25-pin RS-485 connector
$30
Ordering Examples:
1.) INFW-0200-DC7, Standard Panel Meter with two relays, ▒50 mV input, 115 Vac power and red LED display, $595 + 75 = $670.
2.) INFZW-2210-DC1 Split Meter, two relays, analog output and 0-100 mVdc input, 115 Vac power and green LED display, $645 + 75 + 110 = $830.



Fast  Quotes on Products

HOME / PRODUCT GUIDE / TECHNICAL REFERENCE
NEWPORT Electronics, Inc. (714) 540-4914 or Contact Us
Copyright 1999, Newport Electronics, Inc. All rights reserved.